Sign In | Join Free | My infospaceinc.com
China Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd. logo
Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Qindiyuan-Milano | For Oil & Gas, Smart Instruments & Explosion-Proof Robots
Verified Supplier

1 Years

Home > Pressure Measurement Instruments‌ >

HART 7 Protocol Temperature Transmitter PR 5437D with SIL 2 Certification and IP68 Protection for Industrial Applications

Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

HART 7 Protocol Temperature Transmitter PR 5437D with SIL 2 Certification and IP68 Protection for Industrial Applications

  • 1
  • 2
  • 3

Brand Name : PR

Model Number : PR 5437D

Certification : CO

Place of Origin : Denmark

MOQ : 1

Price : 174usd

Payment Terms : T/T

Supply Ability : 99pcs 4-6 weeks

Delivery Time : 5-7 work days

Accuracy : ±0.5% FS

Outputsignal : 4-20 mA, 0-10 V

Operatingtemperature : -20°C to 80°C

Connectiontype : 1/4 inch NPT

Protectionrating : IP65

Responsetime : ≤ 1 second

Displaytype : Digital LCD

Material : Stainless Steel

Mountingtype : Panel Mount, Wall Mount

Productname : Pressure Measurement Instruments

Powersupply : 24 V DC

Measurementrange : 0 to 1000 psi

Application : Industrial, HVAC, Automotive

Pressuretype : Gauge, Absolute, Differential

Contact Now

PR 5437D 2-Wire HART 7 Temperature Transmitter
Product Overview

Advanced 2-wire HART 7 temperature transmitter supporting RTD, TC, potentiometer, linear resistance, and bipolar mV inputs. Features single or true dual inputs with sensor redundancy and drift detection capabilities.

Environmental Conditions
Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL)
Storage temperature -50°C to +85°C
Calibration temperature 23...25°C
Relative humidity < 99% RH (non-condensing)
Protection degree (enclosure/terminal) IP68 / IP00
Mechanical Specifications
Dimensions Ø 44 x 21.45 mm
Center hole diameter Ø 6.35 mm / ¼ in
Weight approx. 50 g
Wire size 1 x 1.5 mm² stranded wire
Screw terminal torque 0.4 Nm
Vibration IEC 60068-2-6
2...25 Hz: ±1.6 mm
25...100 Hz: ±4 g
Common Specifications
Supply
Supply voltage 7.5*...30** VDC
Internal power dissipation ≤ 850 mW
Additional min. supply voltage when using test terminals 0.8 V
Min. load resistance at >37 V supply (Vsupply - 37) / 23 mA
Isolation Voltage
Isolation voltage, test / working 2.5 kVAC / 42 VAC
Performance Characteristics
Response time 75 ms
Programmable damping 0...60 s
Polarity protection All inputs and outputs
Warm-up time < 5 min.
Start-up time < 2.75 s
Programming HART & PR 5909 Loop Link communications interface
Write protection Jumper or software
Signal / noise ratio > 60 dB
Long-term stability, better than ±0.05% of span / year (±0.18% of span / 5 years)
Signal dynamics, input 24 bit
Signal dynamics, output 18 bit
Effect of supply voltage change < 0.005% of span / VDC
Accuracy See manual for details
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1%
Input Specifications
RTD Input
RTD type Pt10...10000, Ni10...10000, Cu5...1000
Cable resistance per wire 50 Ω (max.)
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor current < 0.15 mA
Sensor error detection None, Shorted, Broken, Shorted or Broken
TC Input
Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC) Constant, internal or external via a Pt100 or Ni100 sensor
Sensor error detection None, Shorted, Broken, Shorted or Broken
Linear Resistance Input
Measurement range / min. range (span) 0 Ω...100 kΩ / 25 Ω
Cable resistance per wire (max.) 50 Ω
Sensor current < 0.15 mA
Sensor error detection None, Broken
Potentiometer Input
Potentiometer min....max. 10 Ω...100 kΩ
Measurement range / min. range (span) 0...100% / 10%
Cable resistance per wire (max.) 50 Ω
Sensor current < 0.15 mA
Sensor error detection None, Shorted, Broken, Shorted or Broken
mV Input
Measurement range -800...+800 mV (bipolar) -100...1700 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Sensor error detection None, Broken
Output Specifications
Normal range, programmable 3.8...20.5 / 20.5...3.8 mA
Extended range (output limits), programmable 3.5...23 / 23...3.5 mA
Updating time 10 ms
Load (@ current output) ≤ (Vsupply -7.5)/0.023 [Ω]
Load stability < 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE 43 Upscale/Downscale > 21 mA / < 3.6 mA
HART protocol revisions HART 7 and HART 5
Compliance & Approvals
Authority Requirements
EMC 2014/30/EU & UK SI 2016/1091
ATEX 2014/34/EU & UK SI 2016/1107
RoHS 2011/65/EU & UK SI 2012/3032
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Certifications & Approvals
ATEX DEKRA 16ATEX0047X
IECEx IECEx DEK. 16.0029X
CSA CSA 16.70066266
c FM us FM16US0287X / FM16CA0146X
INMETRO DEKRA 23.0002X
NEPSI GYJ23.1227X
EAC Ex EAEU KZ 7500361.01.01.08756
EU RO MR Type Approval MRA0000023
SIL SIL 2 / SIL 3 certified & fully assessed acc. to IEC 61508
Additional Information
NAMUR NE95 report Please contact us
* / ** See manual for details

Product Tags:

HART 7 Protocol Temperature Transmitter

      

SIL 2 Certified HART Transmitter

      

IP68 Protection PR 5437D

      
Quality HART 7 Protocol Temperature Transmitter PR 5437D with SIL 2 Certification and IP68 Protection for Industrial Applications for sale

HART 7 Protocol Temperature Transmitter PR 5437D with SIL 2 Certification and IP68 Protection for Industrial Applications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)