| Sign In | Join Free | My infospaceinc.com |
|
Brand Name : PR
Model Number : PR 5334A
Place of Origin : Denmark
MOQ : 1
Price : 95USD
Payment Terms : T/T
Supply Ability : 99PCS 4-6 WEEKS
Delivery Time : 5-7 work days
Operatingtemperature : -40°C to 85°C
Material : Stainless Steel, Brass
Ingressprotection : IP65, IP67
Calibration : Factory calibrated, Field calibratable
Application : Industrial, HVAC, Automotive, Oil & Gas
Pressuretype : Gauge, Absolute, Differential
Productname : Pressure Measurement Instruments
Measurementrange : 0 to 1000 psi
Powersupply : 24 V DC
Displaytype : LCD, LED
Outputsignal : 4-20 mA, 0-10 V, Digital
Responsetime : ≤ 1 ms
Connectiontype : Threaded, Flanged
Accuracy : ±0.25% of full scale
| Operating temperature | -40°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-condensing) |
| Protection degree (enclosure/terminal) | IP68 / IP00 |
| Dimensions | Ø 44 x 20.2 mm |
| Weight approx. | 50 g |
| Wire size | 1 x 1.5 mm² stranded wire |
| Screw terminal torque | 0.4 Nm |
| Vibration | IEC 60068-2-6 2...25 Hz: ±1.6 mm 25...100 Hz: ±4 g |
| ATEX | II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc |
| IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
| INMETRO | Ex ec [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc |
| EMC | 2014/30/EU |
| ATEX | 2014/34/EU |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
| ATEX | DEKRA 20ATEX0096X |
| IECEx | DEK 20.0059X |
| INMETRO | DEKRA 23.0009X |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |
| DNV Marine | TAA0000101 |
|
|
2 Wire Industrial Programmable Transmitter PR 5334A High Accuracy Galvanic Isolation TC Input Images |