Brand Name : PR

Model Number : PR 5335A

Place of Origin : Denmark

MOQ : 1

Price : 95usd

Payment Terms : T/T

Supply Ability : 99pcs 4-6 weeks

Delivery Time : 5-8 work days

Coo : Yes

Signal Isolation : Galvanic Isolation

Manufacturer : Sick

Material : 316 Stainless Steel

Weight : 0.5KG

Generic Code : SICK8

Measurement Range : -200°C to 850°C

Actuator Type : Side Rotary - No Lever

Input Protection : Internally fused, non-replaceable

Color : Black and blue

Aprroval : None

Response Times : as fast as 90ms

Stage Design : stage design with dry torque Motor

Range : -200℃-1200℃

Product No : VE4005S2B1

Contact Now

2-Wire Transmitter with HART Protocol - PR 5335A
RTD, TC, Ohm, or mV input capability
Extremely high measurement accuracy
HART 5 protocol compatibility
Programmable sensor error value
Designed for DIN form B sensor head mounting
Environmental Conditions
Parameter Specification
Operating temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-condensing)
Protection degree (enclosure/terminal) IP68 / IP00
Mechanical Specifications
Parameter Specification
Dimensions Ø 44 x 20.2 mm
Weight approx. 50 g
Wire size 1 x 1.5 mm² stranded wire
Screw terminal torque 0.4 Nm
Vibration (IEC 60068-2-6) 2...25 Hz: ±1.6 mm
25...100 Hz: ±4 g
Common Specifications
Supply
Supply voltage 8.0...35 VDC
Isolation Voltage
Isolation voltage, test / working 1.5 kVAC / 50 VAC
Response Time
Response time (programmable) 1...60 s
Warm-up time 30 s
Programming HART & PR 5909 Loop Link communications interface
Performance
Signal / noise ratio > 60 dB
Accuracy Better than 0.05% of selected range
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
Input Specifications
Common Input Specifications
Max. offset 50% of selected max. value
RTD Input
RTD type Pt100, Ni100, lin. R
Cable resistance per wire 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor current Nom. 0.2 mA
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor error detection Yes
TC Input
Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC) < ±1.0°C
Sensor error detection Yes
Sensor error current: When detecting / else Nom. 33 μA / 0 μA
Voltage Input
Measurement range -800...+800 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Output Specifications
Current Output
Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Load stability ≤ 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
Intrinsic Safety / Ex Marking
Standard Certification
ATEX II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc
IECEx Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc
CSA Cl. I, Div. 2, Gp. A, B, C, D T6...T4, Ex nA[ic] IIC T6…T4 Gc
INMETRO Ex ec [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc
Compliance with Authority Requirements
Standard Directive
EMC 2014/30/EU
ATEX 2014/34/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Approvals
Standard Certificate
ATEX DEKRA 20ATEX0109X
IECEx DEK 20.0063X
CSA 1125003
INMETRO DEKRA 23.0011X
EAC Ex EAEU KZ 7500361.01.01.08756
DNV Marine TAA0000101
SIL Hardware assessed for use in SIL applications

Product Tags:

HART 5 Protocol Temp Transmitters

      

2 Wire Temp Transmitters

      
Quality HART 5 Protocol 2 Wire Temp Transmitters PR 5335A With Programmable Sensor Error Value for sale