PR 3102 Pt100 converter 0.1% accuracy excellent EMC performance selectable response time

Brand Name : PR

Model Number : PR 3102

Certification : CO

Place of Origin : Denmark

MOQ : 1

Price : 200-400usd

Payment Terms : T/T

Supply Ability : 99pcs 4-6 weeks

Delivery Time : 5-7 work days

Absolute Encoders : AFS/AFM60

Coo : Yes

Storage Temperature : -40 to 70°C (-40 to 158°F)

Mounting : DIN Rail or Field Mount

Power Supply : 24 V DC

Tariff Code : 85365080

Display : Optional LCD

Body : Brass

Manufacture : DeltaV

Electrical Connection : Screw Terminals

Shipping Weight : 5KG

Fuse Protection : 3.0 A, non-replaceable fuses

Compensation Rangeability : up to 400:1

Package : Bulk

Input Type : RTD, Thermocouple

Contact Now

Pt100 Converter
PR 3102
  • Excellent accuracy, better than 0.1% of span
  • Excellent EMC performance and 50/60 Hz noise suppression
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature measurement
Environmental Conditions
Operating temperature -25°C to +70°C
Storage temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20
Installation in Pollution degree 2 & meas. / overvoltage cat. II
Mechanical Specifications
Dimensions (HxWxD) 113 x 6.1 x 115 mm
Weight approx. 70 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.5 mm² / AWG 26...12 stranded wire
Screw terminal torque 0.5 Nm
Vibration IEC 60068-2-6
2...25 Hz ±1.6 mm
25...100 Hz ±4 g
Common Specifications
Supply
Supply voltage 16.8...31.2 VDC
Max. required power 0.52 W
Max. power dissipation 0.52 W
Response Time
Response time (0...90%, 100...10%) < 30 ms / 300 ms (selectable)
Signal / noise ratio Min. 60 dB
Programming DIP switches
Signal dynamics, input 23 bit
Signal dynamics, output 18 bit
Accuracy Better than 0.1% of sel. range
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
Incorrect DIP-switch setting identification 0 V / 0 mA output; LED 0.5 s / 1 Hz
Input Specifications
RTD Input
Temperature range, Pt100 -200...+850°C
Min. measurement range (span) 10°C
Accuracy: the greater of Better than 0.1% of span or 0.2°C
Temperature coefficient: the greater of 0.02°C/°C or ≤ ±0.01%/°C
Sensor current < 150 µA
Sensor cable resistance < 50 Ω per wire
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor error detection Yes - selectable via DIP-switch
Broken sensor detection > 800 Ω
Shorted sensor detection < 18 Ω
Output Specifications
Common Output Specifications
Updating time 10 ms
Current Output
Signal range 0...23 mA
Programmable signal ranges 0 / 4...20 mA
Sensor error indication (0...20 mA) 0 mA or 23 mA / OFF
Sensor error indication (4...20 mA) 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limitation @ low output load < 60 mA peak / < 4 mA average
Voltage Output
Programmable signal ranges 0/1...5 and 0/2...10 V
Sensor error indication 0 V / 10% above the max. / none
Load (@ voltage output) ≥ 10 kΩ
Open output < 18 V
I.S. / Ex Marking
ATEX II 3 G Ex ec IIC T4 Gc
IECEx Ex ec IIC T4 Gc
FM, US Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CA Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
EAC Ex 2Ex nA IIC T4 Gc X
Observed Authority Requirements
EMC 2014/30/EU & UK SI 2016/1091
LVD 2014/35/EU & UK SI 2016/1101
ATEX 2014/34/EU & UK SI 2016/1107
RoHS 2011/65/EU & UK SI 2012/3032
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Approvals
ATEX KEMA 10ATEX0147 X
IECEx KEM 10.0068X
UKEX DEKRA 21UKEX0055X
c FM us FM17US0004X / FM17CA0003X
c UL us, UL 61010-1 E314307
EAC Ex EAEU KZ 7500361.01.01.08756
DNV Marine TAA00001RW

Product Tags:

Pt100 converter with high accuracy

      

temperature transmitter with EMC performance

      

pre-calibrated Pt100 temperature converter

      
Quality PR 3102 Pt100 converter 0.1% accuracy excellent EMC performance selectable response time for sale

PR 3102 Pt100 converter 0.1% accuracy excellent EMC performance selectable response time Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)